Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing
Impulse Voltage Generator For Power Transformer Testing

Impulse Voltage Generator For Power Transformer Testing

Price 10000 USD ($)/ Set

MOQ : 1 Unit

Impulse Voltage Generator For Power Transformer Testing Specification

  • Load Loss
  • 2 kW
  • Dimension (L*W*H)
  • 3200 mm 1900 mm 3700 mm
  • Voltage Booster Type
  • Impulse capacitive voltage divider
  • Low Voltage
  • 400 V - 415 V AC
  • Coil Material
  • Copper
  • Operating Temperature
  • -10C to +50C
  • Capacity
  • Up to 360 kV/500 kJ
  • Rated Voltage
  • Up to 1800 kV impulse
  • Cooling Type
  • Air Cooled
  • High Voltage
  • 1800 kV
  • Standard
  • IEC 60060, IS 2071
  • Product Type
  • Impulse Voltage Generator
  • Material
  • Mild Steel, High-grade Insulation Components
  • Output
  • Impulse voltage waveform
  • Frequency (MHz)
  • Up to 1 MHz
  • Efficiency
  • 98%
  • Phase
  • Three Phase
  • Usage
  • For testing power transformers and insulation materials by simulating lightning and switching impulses.
  • Coil Structure
  • Multi-layer cylindrical
  • Coil Number
  • Multi-coil arrangement
  • Power Scope
  • Up to 2000 kVA
  • Weight
  • Approx. 3200 kg
  • Mounting
  • Skid mounted with castor wheels for mobility
  • Impulse Waveform
  • Standard Lightning and Switching Impulse (1.2/50 s, 250/2500 s)
  • Humidity Range
  • 85% RH (non-condensing)
  • Impulse Energy
  • 500 kJ
  • Test Object Capacity
  • Compatible for power transformers up to 160 MVA
  • Number of Stages
  • 10 stages (customizable)
  • Safety Features
  • Over-voltage protection, Interlock system, Emergency stop
  • Polarity
  • Both polarity (positive and negative) generation supported
  • Discharge Resistor
  • Oil-immersed discharge resistor bank
  • Measuring Range
  • 100 kV 1800 kV
  • Control System
  • PLC-based fully automated operation
 

Impulse Voltage Generator For Power Transformer Testing Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 60 Days
 

About Impulse Voltage Generator For Power Transformer Testing

Impulse voltage generator system

Main Description :  This system is used for lightning impulse voltage full wave, chopped wave and operating impulse voltage testing to check the insulation performance. It is suitable for power transformer, distribution transformer, PT, CT, arrester, and related electrical equipment. The system mainly consists of generator, chopper, voltage divider, control cabinet, digital wave oscilloscope, etc.

Main Features:

  • The loop inductance is small, and takes the band-stop filter measures, under large load capacity can produce standard shock
  • The voltage utilization factor is high, lightning and operating wave no less than 85% and 80%
  • Easy operation, good synchronizing performance, reliable operation
  • Constant current charging automatic control technology, high degree of automation and anti-jamming capability.



Advanced Testing for Power Transformers

Designed for rigorous assessment, this impulse voltage generator simulates real-world lightning and switching impulses to test power transformers and insulation materials. Its high voltage capability and fully automated operation streamline the testing process, ensuring reliable results for transformers up to 160 MVA.


Safety, Efficiency, and Mobility

Safety remains paramount with integrated over-voltage protection, interlock systems, and emergency stops. The air-cooled, skid-mounted generator boasts 98% efficiency and castor wheels, allowing easy movement within testing facilities. Its multi-layer coil structure and oil-immersed discharge resistors guarantee stable, repeatable performance.

FAQs of Impulse Voltage Generator For Power Transformer Testing:


Q: How does the impulse voltage generator simulate lightning and switching impulses during transformer testing?

A: The generator produces standard impulse waveforms of 1.2/50 s for lightning and 250/2500 s for switching, replicating real-world electrical stresses encountered by power transformers. This ensures comprehensive evaluation of insulation and operational reliability.

Q: What safety features are incorporated to protect operators during testing?

A: Safety is ensured through over-voltage protection, an interlock system that prevents unauthorized operation, and an emergency stop function. These measures protect both the testing personnel and the equipment throughout operation.

Q: When is impulse voltage testing required for power transformers?

A: Impulse voltage testing is typically performed during final inspection and quality assurance of power transformers to assess their insulation strength and resilience against electrical transients, especially before deployment in substations or grid integration.

Q: Where can this generator be installed and used effectively?

A: Thanks to its skid-mounted design with castor wheels, the unit offers easy mobility and can be installed in testing laboratories, manufacturing sites, or transformer service centers across India, wherever power transformer and insulation material testing is necessary.

Q: What automated features streamline the impulse testing process?

A: A fully automated PLC-based control system enables precise operation, quick setup, and real-time monitoring of waveforms and discharge cycles, allowing efficient management and error reduction in testing workflows.

Q: How does mobile mounting benefit the testing workflow?

A: The generators skid-mounted base with castor wheels allows quick relocation within the facility, optimizing space and enabling flexible arrangement for transformer connections and multiple test setups.

Q: What are the main benefits of using this impulse voltage generator for transformer manufacturers?

A: Using this system, manufacturers gain reliable, repeatable test results, compliance with IEC 60060 and IS 2071 standards, and enhanced product quality assurance, securing confidence in transformer performance across high-voltage applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transformer Testing Equipment Category

Automatic Integrated Test System For Testing Power Transformer

Automatic Integrated Test System For Testing Power Transformer

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Coil Number : Other, Multiple

Low Voltage : Up to 35 kV

Voltage Booster Type : Other, Automatic

Dimension (L*W*H) : 1400 x 1200 x 1800 mm

Transformer Winding Resistance Ohmmeter

Transformer Winding Resistance Ohmmeter

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Coil Number : Other, Supports measurement per winding

Low Voltage : Applicable to low voltage windings

Voltage Booster Type : Other, Solid state controlled booster

Dimension (L*W*H) : 360 x 300 x 180 mm

Electrical Silicon Steel Iron Loss Tester

Electrical Silicon Steel Iron Loss Tester

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Coil Number : Other, Standard Single Coil

Low Voltage : 0250V/0500V Adjustable

Voltage Booster Type : Other, Electronic Voltage Booster

Dimension (L*W*H) : 380 x 360 x 260 mm

Partial Discharge Test Equipment For Power Transformer Testing

Partial Discharge Test Equipment For Power Transformer Testing

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Coil Number : Other, Multiple Coils

Low Voltage : 220 V to 1100 V

Voltage Booster Type : Other, Automatic

Dimension (L*W*H) : 700 mm x 400 mm x 600 mm (Approx.)



Back to top